CallFree EstimateSchedule Service

Make-Up Air & Exhaust Systems

Exhaust without make-up air is a building fighting itself — doors that won't open, drafts, backdrafting appliances, and kitchens that can't breathe. Heating & Cooling Two installs and services make-up air and exhaust systems for Twin Cities commercial buildings, with deep experience in restaurants. Since 1980. Call 763-428-3677.

Family-owned since 1980

Three generations of Twin Cities neighbors keeping homes and businesses comfortable.

NATE-certified technicians

Factory-trained, background-checked techs who explain the work before they start.

Bryant Factory Authorized Dealer

Top-tier equipment, factory warranties and rebates you can only get from an authorized dealer.

Restaurants

Restaurant exhaust & make-up air

Commercial kitchens are the hardest ventilation environment there is: hood exhaust, tempered make-up air, interlocks, and code compliance all have to work together or the kitchen doesn't. We design, install, and service complete restaurant ventilation — hood exhaust fans, tempered make-up air units, and the controls that tie them together.

Applications

Who needs make-up air

  • Restaurants and commercial kitchens
  • Manufacturing and workshops with process exhaust
  • Auto shops and paint operations
  • Warehouses with exhaust fans
  • Any building where exhaust CFM exceeds what the envelope can naturally replace

Commercial DuctworkAll Commercial Services

Minnesota code

What Minnesota requires for kitchen make-up air

Minnesota's mechanical code has its own rules for commercial kitchens. They're stricter than the national model code in a few important ways:

  • Make-up air must be supplied whenever the kitchen exhaust is running, in an amount roughly equal to the air being exhausted.
  • Make-up air must be provided mechanically, and the exhaust and make-up air systems must be electrically interlocked so one can't run without the other.
  • Make-up air must be at least 50°F where it leaves the supply diffuser. In a Minnesota winter, that means it has to be heated.
  • Supply diffusers within 12 feet of the hood must point away from it so they don't disrupt smoke and grease capture.

Those rules exist for good reasons. Without enough make-up air, hoods can't capture smoke, doors become hard to open, and gas appliances and water heaters can backdraft exhaust into the building.

Warning signs

Signs your building is short on make-up air

  • Entry doors that are hard to open or slam shut.
  • Cold drafts near doors and windows in winter.
  • Smoke or cooking odors drifting into the dining room.
  • A hood that doesn't pull smoke well, even with clean filters.
  • Pilot lights that blow out, or water heaters with exhaust spilling at the draft hood.
  • Whistling at doors and gaps when the exhaust is on.

If you notice an exhaust smell or a carbon monoxide alarm goes off, shut down gas appliances, get people outside and call for help right away.

Keep it working

Make-up air maintenance

  • Change intake filters on a schedule. Clogged filters starve the kitchen of air.
  • Check burners, igniters and gas safeties on heated make-up air units every fall.
  • Inspect belts, bearings and motors on exhaust fans and supply fans.
  • Confirm the interlock still starts make-up air whenever the hood fan runs.
  • Check that the discharge temperature stays at or above 50°F in cold weather.

Call 763-428-3677 for make-up air design, installation or service.

Commercial HVACTesting & BalancingCommercial Ductwork

FAQ

Make-up air questions, answered

Why does my restaurant's kitchen get smoky when the hood is running?

Almost always insufficient make-up air — the hood can't exhaust what the building won't replace. A properly sized, tempered make-up air unit fixes it.

What is tempered make-up air?

Incoming replacement air that's heated (or cooled) before it enters the space — essential in Minnesota, where raw winter air would freeze out your kitchen.

Do you service existing make-up air units?

Yes — repair and maintenance on all makes and models, plus replacements when a unit's done.

Does make-up air have to be heated in Minnesota?

For commercial kitchens, yes in practice. Minnesota requires kitchen make-up air to be at least 50°F where it enters the space, which means heating it during cold weather.

Can my exhaust fan run without make-up air?

Not in a commercial kitchen. Minnesota requires the exhaust and make-up air systems to be electrically interlocked so make-up air runs whenever the exhaust runs.

Do you clean kitchen hoods and grease ducts?

Hood and grease-duct cleaning is usually done by specialized cleaning companies. We design, install and service the exhaust fans, make-up air units and controls.

Ready when you are.

Free estimates and straight answers across the Twin Cities. After-hours emergency service available.