Make-Up Air & Exhaust Systems
Exhaust without make-up air is a building fighting itself — doors that won't open, drafts, backdrafting appliances, and kitchens that can't breathe. Heating & Cooling Two installs and services make-up air and exhaust systems for Twin Cities commercial buildings, with deep experience in restaurants. Since 1980. Call 763-428-3677.
Family-owned since 1980
Three generations of Twin Cities neighbors keeping homes and businesses comfortable.
NATE-certified technicians
Factory-trained, background-checked techs who explain the work before they start.
Bryant Factory Authorized Dealer
Top-tier equipment, factory warranties and rebates you can only get from an authorized dealer.
Restaurants
Restaurant exhaust & make-up air
Commercial kitchens are the hardest ventilation environment there is: hood exhaust, tempered make-up air, interlocks, and code compliance all have to work together or the kitchen doesn't. We design, install, and service complete restaurant ventilation — hood exhaust fans, tempered make-up air units, and the controls that tie them together.
Applications
Who needs make-up air
- Restaurants and commercial kitchens
- Manufacturing and workshops with process exhaust
- Auto shops and paint operations
- Warehouses with exhaust fans
- Any building where exhaust CFM exceeds what the envelope can naturally replace
Minnesota code
What Minnesota requires for kitchen make-up air
Minnesota's mechanical code has its own rules for commercial kitchens. They're stricter than the national model code in a few important ways:
- Make-up air must be supplied whenever the kitchen exhaust is running, in an amount roughly equal to the air being exhausted.
- Make-up air must be provided mechanically, and the exhaust and make-up air systems must be electrically interlocked so one can't run without the other.
- Make-up air must be at least 50°F where it leaves the supply diffuser. In a Minnesota winter, that means it has to be heated.
- Supply diffusers within 12 feet of the hood must point away from it so they don't disrupt smoke and grease capture.
Those rules exist for good reasons. Without enough make-up air, hoods can't capture smoke, doors become hard to open, and gas appliances and water heaters can backdraft exhaust into the building.
Warning signs
Signs your building is short on make-up air
- Entry doors that are hard to open or slam shut.
- Cold drafts near doors and windows in winter.
- Smoke or cooking odors drifting into the dining room.
- A hood that doesn't pull smoke well, even with clean filters.
- Pilot lights that blow out, or water heaters with exhaust spilling at the draft hood.
- Whistling at doors and gaps when the exhaust is on.
If you notice an exhaust smell or a carbon monoxide alarm goes off, shut down gas appliances, get people outside and call for help right away.
Keep it working
Make-up air maintenance
- Change intake filters on a schedule. Clogged filters starve the kitchen of air.
- Check burners, igniters and gas safeties on heated make-up air units every fall.
- Inspect belts, bearings and motors on exhaust fans and supply fans.
- Confirm the interlock still starts make-up air whenever the hood fan runs.
- Check that the discharge temperature stays at or above 50°F in cold weather.
Call 763-428-3677 for make-up air design, installation or service.
FAQ
Make-up air questions, answered
Why does my restaurant's kitchen get smoky when the hood is running?
Almost always insufficient make-up air — the hood can't exhaust what the building won't replace. A properly sized, tempered make-up air unit fixes it.
What is tempered make-up air?
Incoming replacement air that's heated (or cooled) before it enters the space — essential in Minnesota, where raw winter air would freeze out your kitchen.
Do you service existing make-up air units?
Yes — repair and maintenance on all makes and models, plus replacements when a unit's done.
Does make-up air have to be heated in Minnesota?
For commercial kitchens, yes in practice. Minnesota requires kitchen make-up air to be at least 50°F where it enters the space, which means heating it during cold weather.
Can my exhaust fan run without make-up air?
Not in a commercial kitchen. Minnesota requires the exhaust and make-up air systems to be electrically interlocked so make-up air runs whenever the exhaust runs.
Do you clean kitchen hoods and grease ducts?
Hood and grease-duct cleaning is usually done by specialized cleaning companies. We design, install and service the exhaust fans, make-up air units and controls.
Ready when you are.
Free estimates and straight answers across the Twin Cities. After-hours emergency service available.