Furnace Pressure Switch: Why Your Furnace Won't Light and What Causes It
Inducer fan runs but the furnace won't light? The pressure switch may be stopping it. What it does, what trips it in a Minnesota winter and what to check.
Read articleSome frost on a heat pump in winter is normal. How the defrost cycle works, when ice means trouble, and what to safely do in a Minnesota winter.
Family-owned since 1980
Three generations of Twin Cities neighbors keeping homes and businesses comfortable.
NATE-certified technicians
Factory-trained, background-checked techs who explain the work before they start.
Bryant Factory Authorized Dealer
Top-tier equipment, factory warranties and rebates you can only get from an authorized dealer.

October 29, 2026 · 7 min read
By Trevor Torgerson, Manager, Sales & Operations
If you've recently added a heat pump, the first frosty morning can be alarming. The outdoor unit is white with frost, then it starts hissing and steaming, the fan stops, and water runs out the bottom. All of that can be perfectly normal. A heat pump that's a solid block of ice for hours is not.
More Twin Cities homes have heat pumps every year, often paired with a gas furnace in a dual-fuel system. Here's how to tell normal winter frost from a real problem, and what to do about each.
In winter, a heat pump pulls heat out of the outdoor air and moves it inside. To do that, the outdoor coil runs colder than the air around it. When the outdoor temperature is near or below freezing and the air is damp, moisture freezes onto that cold coil, the same way frost forms on a car windshield overnight.
Light frost doesn't hurt anything, but it does block airflow through the coil. So every heat pump has a defrost cycle to clear it.
When the control senses frost building up, it briefly reverses the system, sending warm refrigerant to the outdoor coil to melt the ice. During defrost, you may notice:
A defrost cycle usually lasts a few minutes, up to about 10 or 15, and may happen every half hour to every hour or two in frosty, humid weather. On dry, very cold days, it may defrost less often. All of this is expected.
While the outdoor coil is defrosting, the heat pump isn't heating the house. Most systems cover that gap automatically. In an all-electric heat pump system, electric backup heat strips in the indoor air handler switch on for a few minutes so the vents don't blow cold. In a dual-fuel system, the thermostat or control usually brings on the gas furnace instead.
Your thermostat may show messages like "defrost," "aux heat" or "auxiliary heat on" during that time. A short burst of backup heat during defrost is normal. Backup heat running for hours on a mild day is not, and it can raise your electric bill quickly. If you notice that, or the thermostat shows auxiliary heat constantly when it isn't very cold, have the system checked. A setting or sensor problem may be keeping the heat pump from doing its share of the work.
Those point either to an outside cause, like dripping water or poor drainage, or to a problem with the heat pump itself, such as a failed defrost sensor or control, a stuck reversing valve, a fan motor problem or low refrigerant.
Many winter ice problems start with where the unit sits. A heat pump under a roof edge without gutters gets dripped on all winter. One sitting on a pad at ground level can end up buried in drifted snow or frozen into its own defrost water. That's why heat pumps in snowy climates are usually installed on a raised stand or wall bracket, away from roof runoff, with room for water to drain.
If your heat pump was set at ground level and keeps freezing up, raising it may solve the problem. Our online shop carries heat pump and mini-split stands, and we can assess placement during a service visit.
It's tempting to protect the unit with a cover or tarp, but a heat pump runs all winter and needs open airflow. Covering it can stop it from heating and damage the equipment. Our post on covering your AC for winter explains the difference between an air conditioner and a heat pump in winter.
Today's cold-climate heat pumps keep producing heat well below zero, and in a dual-fuel setup the furnace takes over on the coldest nights. Our guide to cold-climate heat pumps in Minnesota covers how they work and who they make sense for. If you're considering one, our heat pumps page explains the options we install.
Call if your heat pump stays iced over for more than a couple of hours, if the fan won't run, if you hear grinding or loud buzzing, or if the house can't stay warm. An annual maintenance plan visit checks the defrost controls, refrigerant charge and fan before the season starts.
Call Heating & Cooling Two at 763-428-3677 or request service. Office hours are Monday through Friday, 7:30 a.m. to 4:30 p.m., and after-hours emergency service is available.
Keep reading

Inducer fan runs but the furnace won't light? The pressure switch may be stopping it. What it does, what trips it in a Minnesota winter and what to check.
Read article
A CO alarm can be warning you of danger, asking for a battery or telling you it's expired. How to tell the difference, what to do right away and when to call.
Read article
Radiators cold at the top or gurgling? How to bleed hot water radiators safely, tell steam from hot water, and read your boiler pressure gauge.
Read articleFree estimates and straight answers across the Twin Cities. After-hours emergency service available.